Specifications

Main
Sherry MasterPacT
Product Name MasterPacT MTZ2
Product or Component Type Circuit breaker
Product Group MTZ2 25 H1
Device Application Power distribution
Definition of Pole 4P
protected pole description 4P 4d 4P 3d + N/2 4P 3d + OSN 4P 3d
neutral position Left
[In] nominal current 2500 A at 40 °C
Performance type H1 66 kA 440 V AC
[Ue] nominal operating voltage 690V AC 50/60Hz
suitability for insulation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
Control type Manually operated ON/OFF push-button
Mounting Type Still
Opening Unit Name MicroLogic Active 2.0 E
opening unit technology Electronic
Trip Unit Protection Functions L.I.
Sensor rating 1250A 1600A 2000A 2500A
Complement
[Icu] rated ultimate short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 525 V AC 50/60 Hz 66 kA at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 525 V AC 50/60 Hz 66 kA at 690 V AC 50/60 Hz
[Icw] rated short-time withstand current 66 kA 0.5 s 66 kA 1 s 36 kA 3 s
[Icm] rated short-circuit making capacity 145 kA at 220/415 V AC 50/60 Hz 145 kA at 440 V AC 50/60 Hz 145 kA at 525 V AC 50/60 Hz 145 kA at 690 V AC 50/60 Hz
[Ui] nominal insulation voltage 1000V AC 50/60Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 260W
power distribution per pole 65W
maximum cutting time 25ms
Maximum closing response time 70ms
Assembly Support Base plate Rails
top link Horizontal
downlink Horizontal
mechanical strength 20000 cycles with maintenance
electrical resistance 5000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 2500 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
protection type Overload protection (long time) conforming to ANSI 49 Momentary short-circuit protection conforming to ANSI 50
opening unit degree 250 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.4...1 x In adjustable in step of 1 A
Long-time protection delay adjustment type tr Adjustable in 0.5 s steps
[tr] long-time protection delay adjustment range 0.5…30 ​​s at 6 x Ir
thermal memory Yes
Neutral protection setting 1 x Ir (4P 4d) 0.5 x Ir (4P 3d + N/2) 1.6 x Ir (4P 3d + OSN) Unshielded (4P 3d)
Instantaneous protection pick-up adjustment type Ii Adjustable
[ii] instantaneous protection pick-up adjustment range 1.5...10 x Ir adjustable in step of 0.1 x Ir
[li mode] instantaneous delay adjustment range 20ms standard
earth leakage protection None
field selective locking ZSI Without
network and machine diagnostic type System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: Test Protection test: Test Selectivity test: Test Trip scope information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state
type of measurement Energy meter Ammeter
energy management Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy
measurement type Current I1, I2, I3, Iavg RMS Neutral current IN RMS Ground fault current Ig RMS Voltage V12, V23, V31, VLLavg RMS Voltage V1N, V2N, V3N, VLNavg RMS Active power P, P1, P2, P3 total Active energy Ep IN/OUT/tot Power factor Demand current I1, I2, I3, In, Iavg Frequency Phase sequence Unbalance current
measuring voltage 208…828 V AC 50/60 Hz phase-to-phase 120…480 V AC 50/60 Hz phase-to-neutral
frequency measuring range 40…70Hz
measurement accuracy Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 1.5 % 40...4000 x 1.2 A Neutral current IN: +/- 1.5 % Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5 % 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 2 % Active energy Ep IN/OUT/tot: +/- 2 % Power factor: +/- 2 % Frequency: +/- 0.005 Hz Unbalance current: +/- 0.5 %
accuracy class Class 0.5: Unbalanced voltage
screen type LCD screen - 320x240 pixels
local signaling Trip causes: 2 LED Status indication: 3 LED
communication port protocol NFC peer-to-peer 28800 bauds compliantISO 15963 USB peer-to-peer 115 kbaud
data recording Data logs Event logs Alarm logs Time stamp Maintenance logs Minimum/maximum of instantaneous values
end user smartphone application EcoStruxure Power Commission EcoStruxure Power Device
Width (W) 537mm
Height (H) 352mm
Depth (D) 300mm
Product Weight 65 kg
Environment
Standards EN/IEC 60947-1 EN/IEC 60947-2
Product Certificates CE CCC EAC
IP protection degree IP3X conforming to EN/IEC 60529
IK protection degree IK07 conforming to EN/IEC 62262
degree of contamination 3 conforming to EN/IEC 60664-1
Ambient Air Temperature for Operation -25…70 °C
Temperature derating table 40 °C 2500 A ) 45 °C 2500 A ) 50 °C 2500 A ) 55 °C 2500 A ) 60 °C 2500 A ) 65 °C 2500 A ) 70 °C 2500 A )
Storage Environmental Conditions -40…85 °C
relative humidity 0…95 % conforming to IEC 60068-2-30
working height 0... 2000 m without 2000 m...5000 m with derating factor
Packaging units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 70cm
Package 1 Width 60cm
Package 1 Length 80cm
Package 1 Weight 77 kg
Contract guarantee
Guarantee 18 months

Customers Reviews

There are no reviews yet.

Be the first to review “Circuit Breaker, MasterPacT MTZ2 25H1 Fixed, 4P, 2500A, 66KA/440VAC, MicroLogic 2.0E Active, Manual”

Your email address will not be published. Required fields are marked *

Back to Top
Product has been added to your cart