Specifications
| Series | MasterPacT |
|---|---|
| Product Name | MasterPacT MTZ2 |
| Product or Component Type | Circuit breaker |
| Product Group | MTZ2 25 H1 |
| Device Application | Power distribution |
| Pole Definition | 3P |
| Shielded pole description | 3P 3D |
| [In] rated current | 2500 A at 40 °C |
| Performance type | H1 66 kA 440 V AC |
| [Ue] nominal operating voltage | 690 V AC 50/60 Hz |
| Compliance with insulation | Yes Conforms to EN/IEC 60947-2 |
| Selectivity category | Category B |
| Type of control | ON/OFF push-button with manual operation |
| Mounting Type | Constant |
| Opening Unit Name | MicroLogic Active 2.0 E |
| Opening unit technology | Electronics |
| Opening Unit Protection Functions | LI |
| Sensor rating | 1250 A 1600 A 2000 A 2500 A |
| [Icu] rated ultimate short-circuit breaking capacity | 66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 525 V AC 50/60 Hz 66 kA at 690 V AC 50/60 Hz |
|---|---|
| [Ics] rated service short-circuit breaking capacity | 66 kA at 220/415 V AC 50/60 Hz 66 kA at 440 V AC 50/60 Hz 66 kA at 525 V AC 50/60 Hz 66 kA at 690 V AC 50/60 Hz |
| [Icw] rated short-time withstand current | 66 kA 0.5 s 66 kA 1 s 36 kA 3 s |
| [İcm] rated short-circuit making capacity | 145 kA at 220/415 V AC 50/60 Hz 145 kA at 440 V AC 50/60 Hz 145 kA at 525 V AC 50/60 Hz 145 kA at 690 V AC 50/60 Hz |
| [Ui] nominal insulation voltage | 1000 V AC 50/60 Hz |
| [Uimp] nominal impulse withstand voltage | 12 kV |
| Power dissipation in W | 260 W |
| Power distribution per pole | 86.7 W |
| Maximum cutting time | 25 ms |
| Maximum shutdown response time | 70 ms |
| Mounting Support | Base plate Rails |
| Top link | Horizontal |
| Downlink | Horizontal |
| Mechanical durability | 20000 cycles with maintenance |
| Electrical durability | 5000 cycles 440 V AC 50/60 Hz conforms to EN/IEC 60947-2 2500 cycles 690 V AC 50/60 Hz conforms to EN/IEC 60947-2 |
| Protection type | Conforming to overload protection (long-term)Conforming to ANSI 49 Instantaneous short-circuit protectionConforming to ANSI 50 |
| Opening Unit Degree | 250 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0,4...1 x In adjustable in step of 1 A |
| Long-time protection delay adjustment type en | Adjustable in 0.5 s steps |
| [EN] long-time protection delay adjustment range | 0,5… 30 s at 6 x Ir |
| Thermal memory | Yes |
| Instantaneous protection pick-up adjustment type Ii | Adjustable |
| [ii] instantaneous protection pick-up adjustment range | 1,5...10 x Ir adjustable in step of 0.1 x Ir |
| [li mode] instantaneous delay adjustment range | 20 ms standard |
| Earth leakage protection | No |
| field-selective locking ZSI | Without |
| Network and machine diagnostic type | System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: Test Protection test: Test Selectivity test: Test Opening scope information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state |
| Measurement type | Energy Meter Ammeter |
| Energy management | Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy |
| Measurement type | Current I1, I2, I3, Iavg RMS Voltage V12, V23, V31, VLLavg RMS Effective power P, P1, P2, P3 total Active energy Ep IN/OUT/tot Power factor Demand current I1, I2, I3, In, Iavg Frequency Phase sequence Unequilibrium current |
| Measuring voltage | 208… 828 V AC 50/60 Hz phase-to-phase |
| Frequency measurement range | 40… 70 Hz |
| Measurement accuracy | Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 1.5 % 40...4000 x 1.2 A Voltage V12, V23, V31, VLLavg: +/- 0.5% 208...690 x 1.2 V Voltage V1N, V2N, V3N, VLNavg: +/- 0.5% 120...400 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 2% Active energy Ep IN/OUT/tot: +/- 2% Power factor: +/- 2 % Frequency: +/- 0.005 Hz Unbalance current: +/- %0,5 |
| Accuracy class | Class 0.5: Unbalanced voltage |
| ekran tipi | LCD ekran - 320x240 piksel |
| yerel sinyalleme | Trip causes: 2 LED Status indication: 3 LED |
| haberleşme port protokolü | NFC eşler arası 28800 bauds 'e uygunISO 15963 USB eşler arası 115 kbaud |
| data record | Data records Event records Alarm records Time stamp Maintenance records Minimum/maximum of instantaneous values |
| end user smartphone application | EcoStruxure Power Commission EcoStruxure Power Device |
| Width (W) | 422 mm |
| Height (H) | 352 mm |
| Depth (D) | 300 mm |
| Product Weight | 50 kgs |
| Standards | EN/IEC 60947-1 EN/IEC 60947-2 |
|---|---|
| Product Certifications | CE CCC EAC |
| IP protection rating | IP3X conforming to EN/IEC 60529 |
| Degree of IK protection | Conforms to IK07 according to EN/IEC 62262 |
| Degree of contamination | Conforms to 3 EN/IEC 60664-1 |
| Ambient Air Temperature for Study | -25… 70°C |
| Temperature derating table | 40 °C 2500 A ) 45 °C 2500 A ) 50 °C 2500 A ) 55 °C 2500 A ) 60 °C 2500 A ) 65 °C 2500 A ) 70 °C 2500 A ) |
| Storage Environment Conditions | -40… 85°C |
| Relative humidity | 0… 95% conforms to IEC 60068-2-30 |
| Working altitude | 0...2000 m without 2000 m... With a depreciation factor of 5000 m |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 70 cm |
| Package 1 Width | 60 cm |
| Package 1 Length | 80 cm |
| Package 1 Weight | 62 kgs |
| Warranty | 18 months |
|---|







There are no reviews yet.