Circuit Breaker, MasterPacT MTZ1 12H1 Fixed, 3P, 1250A, 42KA/440VAC, MicroLogic 2.0E Active, Manual

0 Reviews
In stock

  • Estimated delivery time 14-30 days
  • 18 months warranty at Genuine Warranty Center.
  • Whats in the box: charging cable and block

Specifications

Main
Sherry MasterPacT
Product Name MasterPacT MTZ1
Product or Component Type Circuit breaker
Product Group MTZ1 12 H1
Device Application Power distribution
Definition of Pole 3P
protected pole description 3P 3d
[In] nominal current 1250 A at 40 °C
Performance type H1 42 kA 440 V AC
[Ue] nominal operating voltage 690V AC 50/60Hz
suitability for insulation Yes conforming to EN/IEC 60947-2
Selectivity category Category B
Control type Manually operated ON/OFF push-button
Mounting Type Still
Opening Unit Name MicroLogic Active 2.0 E
opening unit technology Electronic
Trip Unit Protection Functions L.I.
Sensor rating 630A 800A 1000A 1250A
Complement
[Icu] rated ultimate short-circuit breaking capacity 42 kA at 220/415 V AC 50/60 Hz 42 kA at 440 V AC 50/60 Hz 42 kA at 525 V AC 50/60 Hz 42 kA at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 42 kA at 220/415 V AC 50/60 Hz 42 kA at 440 V AC 50/60 Hz 42 kA at 525 V AC 50/60 Hz 42 kA at 690 V AC 50/60 Hz
[Icw] rated short-time withstand current 42 kA 0.5 s 42 kA 1 s 24 kA 3 s
[Icm] rated short-circuit making capacity 88 kA at 220/415 V AC 50/60 Hz 88 kA at 440 V AC 50/60 Hz 88 kA at 525 V AC 50/60 Hz 88 kA at 690 V AC 50/60 Hz
[Ui] nominal insulation voltage 1000V AC 50/60Hz
[Uimp] rated impulse withstand voltage 12 kV
Power dissipation in W 130W
power distribution per pole 43.3W
maximum cutting time 25ms
Maximum closing response time 50ms
Mounting Support Base plate Rails
top link Horizontal
downlink Horizontal
mechanical strength 12500 cycles with maintenance
electrical resistance 6000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 3000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
protection type Overload protection (long time) conforming to ANSI 49 Momentary short-circuit protection conforming to ANSI 50
opening unit degree 250 A 400 A 630 A 800 A 1000 A 1250 A 1600 A 2000 A 2500 A 3200 A 4000 A 5000 A 6300 A
Long-time pick-up adjustment type Ir (thermal protection) Adjustable
[Ir] long-time protection pick-up adjustment range 0.4...1 x In adjustable in step of 1 A
Long-time protection delay adjustment type tr Adjustable in 0.5 s steps
[tr] long-time protection delay adjustment range 0.5…24 s at 6 x Ir
thermal memory Yes
Instantaneous protection pick-up adjustment type Ii Adjustable
[ii] instantaneous protection pick-up adjustment range 1.5...10 x Ir adjustable in step of 0.1 x Ir
[li mode] instantaneous delay adjustment range 20ms standard
earth leakage protection None
field selective locking ZSI Without
network and machine diagnostic type System (HMI) health state overview: circuit breaker health state Contacts state: circuit breaker health state MicroLogic service life: circuit breaker health state Tripping cause indication: circuit breaker tripping cause Identification card: diagnostic data Configured alarms synthesis: diagnostic data Monitored function: diagnostic data Operation: diagnostic data MicroLogic test: Test Protection test: Test Selectivity test: Test Trip scope information: crisis management Operation: advanced diagnostic Breaker service life: circuit breaker health state
type of measurement Energy meter Ammeter
energy management Measurement ,active, reactive and apparent energy Measurement ,electrical network Measurement ,energy
measurement type Current I1, I2, I3, Iavg RMS Voltage V12, V23, V31, VLLavg RMS Active power P, P1, P2, P3 total Active energy Ep IN/OUT/tot Power factor Demand current I1, I2, I3, In, Iavg Frequency Phase sequence Unbalance current
measuring voltage 208…828 V AC 50/60 Hz phase-to-phase
frequency measuring range 40…70Hz
measurement accuracy Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 1.5 % 40...1600 x 1.2 A Voltage V12, V23, V31, VLLavg: +/- 0.5 % 208...690 x 1.2 V Active power P, P1, P2, P3, Pdemand: +/- 2 % Active energy Ep IN/OUT/tot: +/- 2 % Power factor: +/- 2 % Frequency: +/- 0.005 Hz Unbalance current: +/- 0.5 %
accuracy class Class 0.5: Unbalanced voltage
screen type LCD screen - 320x240 pixels
local signaling Trip causes: 2 LED Status indication: 3 LED
communication port protocol NFC peer-to-peer 28800 bauds compliantISO 15963 USB peer-to-peer 115 kbaud
data recording Data logs Event logs Alarm logs Time stamp Maintenance logs Minimum/maximum of instantaneous values
end user smartphone application EcoStruxure Power Commission EcoStruxure Power Device
Width (W) 276mm
Height (H) 301mm
Depth (D) 209mm
Product Weight 14 kg
Environment
Standards EN/IEC 60947-1 EN/IEC 60947-2
Product Certificates CE CCC EAC
IP protection degree IP3X conforming to EN/IEC 60529
IK protection degree IK07 conforming to EN/IEC 62262
degree of contamination 3 conforming to EN/IEC 60664-1
Ambient Air Temperature for Operation -25…70 °C
Temperature derating table 40 °C 1250 A ) 45 °C 1250 A ) 50 °C 1250 A ) 55 °C 1250 A ) 60 °C 1250 A ) 65 °C 1250 A ) 70 °C 1250 A )
Storage Environmental Conditions -40…85 °C
relative humidity 0…95 % conforming to IEC 60068-2-30
working height 0... 2000 m without 2000 m...5000 m with derating factor
Packaging units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 30cm
Package 1 Width 40cm
Package 1 Length 60cm
Package 1 Weight 18kg
Contract guarantee
Guarantee 18 months